National Instruments DIO 6533 Switch User Manual


 
Chapter 5 Signal Timing
DIO 6533 User Manual 5-30 © National Instruments Corporation
Figure 5-26. Burst Mode Output Timing (Default)
Parameter Description Minimum Maximum
Input Parameters
t
pc
PCLK cycle time
50
t
pw
PCLK high pulse duration
20
t
pl
PCLK low pulse duration
20
t
rs
Setup time from REQ valid to PCLK falling
edge
1—
t
rh
Hold time from PCLK to REQ invalid
0—
Output Parameters
t
pa
PCLK to ACK valid
—22
t
ah
Hold time from PCLK to ACK invalid
3—
t
pdo
PCLK to output data valid
—28
t
doh
Hold time from PCLK to output data invalid
5—
All timing values are in nanoseconds.
PCLK
ACK
Data Out
REQ
t
rs
t
pa
t
pdo
t
pw
t
pl
t
pc
t
doh
t
rh
t
ah