National Instruments NI CVS-1450 Series Switch User Manual


 
Appendix B Specifications
NI CVS-1450 Series User Manual B-4 ni.com
IEEE 1394
Number of ports......................................3
Camera Interface.....................................IEEE 1394a
Speed ......................................................100, 200, or 400 Mbps
Available bus power ...............................Refer to the Power Requirements
section
Physical Characteristics
Dimensions .............................................102 mm × 127 mm × 64 mm
(4 in. × 5in. × 2.5 in.)
Weight ....................................................1 kg (2.2 lb)
Refer to Appendix C, Mounting Information, for dimensional drawings of
the CVS-1450 device.
Environmental
The CVS-1450 Series is intended for indoor use only.
Operating temperature
Vertical mounting position..............0 °C to 55 °C
All other positions ...........................0 °C to 45 °C
Maximum altitude...................................2,000 m
Storage temperature................................–20 °C to 85 °C
Humidity.................................................10% to 90% RH, noncondensing
Pollution Degree.....................................2
Operating shock (IEC 68-2-27) ..............50 g, 6 ms half sine,
3 shocks per side;
30 g 11 ms half sine,
3 shocks per side
Operating vibration
Random (IEC 60068-2-34)..............10 Hz to 500 Hz, 5 G
rms
Swept Sine (IEC 60068-2-6) ...........10 Hz to 500 Hz, 5 g