Omron CPM1A Network Card User Manual


 
91
2. Input the word address of the desired word.
SHIFT
CH
*DM
LR
*EM
B
1
00000
CHANNEL LR 01
3. Press the MONTR Key to begin monitoring.
MONTR
cL01
FFFF
The Up or Down Arrow Key can be pressed to display the status of the pre-
vious or next word.
The displayed words status can be changed using the Hexadecimal/BCD
Data Modification operation. Refer to Refer to 4-3-19 Hexadecimal, BCD
Data Modification, 4-3-20 Binary Data Modification, 4-3-21 Signed Decimal
Data Modification, and 4-3-22 Unsigned Decimal Data Modification for
details.
4. Press the CLR Key to end monitoring.
CLR
00000
CHANNEL LR 01
Note The operating mode can be changed without altering the current monitor display
by holding down the SHIFT Key and then changing the operating mode.
The status of up to six bits and words can be monitored simultaneously, although
only three can be shown on the display at any one time.
1, 2, 3... 1. Press the CLR Key to bring up the initial display.
2. Input the address of the first bit or word and press the MONTR Key.
TIM
MONTR
T000
0100
3. Repeat step 2 up to 6 times to display the next addresses to be monitored.
SHIFT
CONT
#
B
1
MONTR
00001 T000
^ OFF 0100
DM
MONTR
D000000001 T000
0000^ OFF 0100
If 4 or more bits and words are being monitored, the bits and words that do
not appear on the display can be displayed by pressing the MONTR Key. If
the MONTR Key is pressed alone, the display will shift to the right.
If more than six bits and/or words are input, monitoring of the bit or word
input first will be canceled.
4. Press the CLR Key to stop monitoring the leftmost bit or word and clear it
from the display.
CLR
00001 T000
^ OFF 0100
5. Press the SHIFT and CLR Keys to end monitoring altogether.
SHIFT CLR
00000
CONT 00001
Note Press the SHIFT Key, CLR Key, and then CLR Key again to return to the initial
Programming Console display with the multiple address monitoring state
unchanged. Press the SHIFT Key and then the MONTR Key from the initial dis-
play to return to the multiple address monitoring state. The monitoring states can
be retained for 6 bits and words.
The operating mode can be changed without altering the current monitor display
by holding down the SHIFT Key and then changing the operating mode.
Multiple Address
Monitoring
Programming Console Operations
Section 4-3