Chapter 4 Settings — [NETWORK] menu
102 - ENGLISH
Example of the E-mail sent for an error
The following E-mail is sent when an error has occurred.
=== Panasonic projector report(ERROR) ===
Projector Type : RW330
Serial No : SW1234567
----- check system -----
MAIN CPU BUS [ OK ]
FAN [ OK ]
INTAKE AIR TEMPERATURE [ OK ]
OPTICS MODULE TEMPERATURE [ OK ]
INTERNAL AIR TEMPERATURE [ OK ]
LIGHT STATUS [ OK ]
INTAKE AIR TEMP.SENSOR [ OK ]
OPTICS MODULE TEMP.SENSOR [ FAILED ]
INTERNAL AIR TEMP.SENSOR [ OK ]
BATTERY [ OK ]
PHOSPHOR WHEEL [ OK ]
(Error code 00 00 00 00 00 00 00 00 00 00 00 02 00 00 00 00)
Intake air temperature :[ 18 degC / 64 degF ]
Optics module temperature :[ 30 degC / 86 degF ]
Internal air temperature :[ 28 degC / 82 degF ]
PROJECTOR RUNTIME 9 H
-------- Current status --------
MAIN VERSION 1.00
NETWORK VERSION 1.00
SUB VERSION 1.00
POWER STATUS POWER=STANDBY
INPUT SIGNAL DVI-D
SIGNAL NAME XGA60
SIGNAL FREQUENCY 48.36kHz / 60.00H
----- Wired Network configuration -----
DHCP Client OFF
IP address 192.168.0.8
MAC address 04:20:9A:00:00:00
Mon Jul 05 14:11:29 2012
----- Memo -----
[ECO management set up] page
You can make settings for the ECO management function of the projector.
Click [Detailed set up] → [ECO management set up].
1
2
3
4
5
6
7
1 [LIGHT POWER]
Select the light source power setting.
2 [AUTO POWER SAVE]
Select [ON] to set [AMBIENT LIGHT DETECTION], [SIGNAL
DETECTION], and [AV MUTE DETECTION].
3 [AMBIENT LIGHT DETECTION]
Enable ([ON])/disable ([OFF]) the ambient light detection
function.
4 [SIGNAL DETECTION]
Enable ([ON])/disable ([OFF]) the signal detection function.
5 [AV MUTE DETECTION]
Enable ([ON])/disable ([OFF]) the AV mute detection function.
6 [NO SIGNAL SHUT-OFF]
Select the time until the projector enters the standby mode
when the signal detection function is used.
7 [Submit]
Update the setting.
Note
f
For detailed description of each setting item, refer to the [PROJECTOR SETUP] menu of the projector
→
[ECO MANAGEMENT]
(
x
page 70).