Q-Logic SN0135524-00 Switch User Manual


 
IBM eServer BladeCenter Fibre Channel Switch Module
IBM BladeCenter Specific Configuration
P
AGE 144 QLOGIC SWITCH INTEROPERABILITY GUIDE
VERSION 1.0, MARCH 2003
3. The Zoning Config—SANbox Manager dialog box displays.
In the Merge Mode list, select Merge Active Zonesets Only. This is equivalent to SW2 mode
in the CLI.
QLogic CLI
NOTE: Use the CLI commands when the QLogic SANbox Manager GUI is not available. The
procedures are the same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
Login: admin
Password: xxxxxxxx
SANbox2 #> admin start
SANbox2 (admin) #> config edit
SANbox2 (admin-config) #> set config zoning
The following options display:
AutoSave (True / False) [True]
Default (All / None) [All ]
MergeMode (Brocade / SW2) [SW2 ]
SANbox2 (admin-config) #> config save
SANbox2 (admin) #> config activate
The configuration will be activated. Please confirm (y/n): [n] y
IBM BladeCenter Specific Configuration
Not applicable.
QLogic Specific Configuration