McDATA Intrepid 6000 Series Directors
Supported Switches and Firmware Versions
P
AGE 222 QLOGIC SWITCH INTEROPERABILITY GUIDE
VERSION 1.0, MARCH 2003
Supported Switches and Firmware Versions
The following QLogic switches have been tested in the QLogic environment and comply with the
FC-SW-2 standard. QLogic switches have tested interoperable with the following switches from
McDATA that comply with the FC-SW-2 standard.
Domain ID Configuration
To ensure that there are no conflicts between switches, we recommend that each switch have an
assigned Domain ID. The following steps show how to set the Domain ID on both the McDATA
switch and the QLogic switch.
The Domain ID should be locked and unique within the 97–127 (0x61–0x7f) range. This is
equivalent to 1–31 on the McDATA switch. The following chart lists the McDATA Domain ID and
the corresponding QLogic Domain ID.
r
QLogic and McDATA Supported Switch and Firmware Versions
Manufacturer Switch Model Firmware Version
QLogic SANbox2-8 Switch 1.3.x and above
SANbox2-16 Switch 1.3.x and above
SANbox2-64 Switch 1.5.x and above
McDATA Intrepid 6064 Director 04.01.02.4 and above
Intrepid 6140 Director 04.01.02.4 and above
McDATA Versus QLogic Domain IDs
McDATA
Domain ID
QLogic
Domain ID
McDATA
Domain ID
QLogic
Domain ID
McDATA
Domain ID
QLogic
Domain ID
1 97 11 107 21 117
2 98 12 108 22 118
3 99 13 109 23 119
4 100 14 110 24 120
5 101 15 111 25 121
6 102 16 112 26 122
7 103 17 113 27 123
8 104 18 114 28 124
9 105 19 115 29 125
10 106 20 116 30 126