Q-Logic SN0135524-00 Switch User Manual


 
Sun StorEdge Network 2 Gb FC Series Switches
Timeout Values
P
AGE 274 QLOGIC SWITCH INTEROPERABILITY GUIDE
VERSION 1.0, MARCH 2003
Sun StorEdge CLI
NOTE: Use the CLI commands when the Sun StorEdge SANbox Manager GUI is not available.
The procedures are the same for the Sun StorEdge Network 2 Gb FC Switch-8, Sun
StorEdge Network 2 Gb FC Switch-16, and Sun StorEdge Network 2 Gb FC Switch-64.
Login: admin
Password: xxxxxxxx
StorEdge 2Gb FC Switch 64 #> show config switch
Use the above command to verify that R_A_TOV is set to 10000 and E_D_TOV is set to 2000. If
these timeout values are not correct, continue with this section. If the settings are correct, no
changes need to be made; proceed with the next appropriate section.
StorEdge 2Gb FC Switch 64 #> admin start
StorEdge 2Gb FC Switch 64 (admin) #> config edit
StorEdge 2Gb FC Switch 64 (admin-config) #> set config switch
The following options display:
AdminState (1=Online, 2=Offline, 3=Diagnostics) [Online]
BroadcastEnabled (True / False) [True]
InbandEnabled (True / False) [True]
DefaultDomainID (decimal value, 1-239) [1]
DomainIDLock (True / False) [True]
SymbolicName (string, max=32 chars) [StorEdge 2Gb FC Switch 64]
R_T_TOV (decimal value, 1-1000 msec) [100]
R_A_TOV (decimal value, 100-100000 msec) [9000] 10000
E_D_TOV (decimal value, 10-20000 msec) [1000] 2000
FS_TOV (decimal value, 100-100000 msec) [5000]
DS_TOV (decimal value, 100-100000 msec) [5000]
PrincipalPriority (decimal value, 1-255) [254]
ConfigDescription (string, max=64 chars) [Default Config]
StorEdge 2Gb FC Switch 64 (admin-config) #> config save
StorEdge 2Gb FC Switch 64 (admin) #> config activate
The configuration will be activated. Please confirm (y/n): [n] y