Q-Logic SN0135524-00 Switch User Manual


 
QLOGIC SWITCH INTEROPERABILITY GUIDE PAGE 9
V
ERSION 1.0, MARCH 2003
Brocade SilkWorm 3200 and SilkWorm 3800 Switches
Integration Checklist
The following steps must be completed to successfully merge Brocade and QLogic fabrics. The
remainder of this section provides detailed instructions and examples.
ATTENTION!!
Backup the current configuration prior to performing the following steps so that the
configuration is available if something goes wrong.
Disruptions in the fabric can occur as a result of performing the following steps. Therefore,
it is recommended that these changes be done during down time or off-peak hours.
Verify that the correct version of switch firmware is installed on each switch (see “Supported
Switches and Firmware Versions” on page 10).
Ensure that each switch has a unique Domain ID and that it falls within the proper range
(see “Domain ID Configuration” on page 11).
Set all switches to the appropriate timeout values (see “Timeout Values” on page 18).
Ensure that all Zone set and Zone names are unique and conform to ANSI T11 standards
(see “Active Zone Set Names” on page 25).
Ensure that all zone members are specified by WWPN (see “Zone Types” on page 31).
Ensure that all Brocade switches are configured for Interoperability mode (see “Operating Mode
Configuration” on page 37).
Ensure that Brocade’s Platform Management Server is disabled (see “Brocade Specific
Configuration” on page 37).
Verify that the fabrics have successfully merged (see “Successful Integration Checklist” on
page 38).