Renesas M16C/6NM Network Card User Manual


 
Rev.2.00 Nov 28, 2005 page 335 of 378
REJ09B0124-0200
M16C/6N Group (M16C/6NK, M16C/6NM) 22. Electric Characteristics (T/V-ver.)
Under development
This document is under development and its contents are subject to change.
VCC = 5V
15
15
ns
ns
ns
ns
ns
External Clock Input Cycle Time
External Clock Input HIGH Pulse Width
External Clock Input LOW Pulse Width
External Clock Rise Time
External Clock Fall Time
Symbol Parameter
Min.
Standard
Unit
Max.
62.5
25
25
t
C
tw(H)
tw(L)
tr
tf
Timing Requirements
(Referenced to VCC = 5V, VSS = 0V, at Topr = 40 to 85°C unless otherwise specified)
Table 22.56 External Clock Input (XIN Input)
ns
ns
ns
TAiIN Input Cycle Time
TAiIN Input HIGH Pulse Width
TAiIN Input LOW Pulse Width
Symbol
Parameter
Min.
Standard
Unit
Max.
100
40
40
Table 22.58 Timer A Input (Gating Input in Timer Mode)
tc(TA)
tw(TAH)
tw(TAL)
Table 22.59 Timer A Input (External Trigger Input in One-shot Timer Mode)
Table 22.60 Timer A Input (External Trigger Input in Pulse Width Modulation Mode)
Table 22.61 Timer A Input (Counter Increment/decrement Input in Event Counter Mode)
ns
ns
ns
TAiIN Input Cycle Time
TAiIN Input HIGH Pulse Width
TAiIN Input LOW Pulse Width
Symbol
Parameter
Min.
Standard
Unit
Max.
400
200
200
t
c(TA)
tw(TAH)
tw(TAL)
ns
ns
ns
TAiIN Input Cycle Time
TAiIN Input HIGH Pulse Width
TAiIN Input LOW Pulse Width
Symbol Parameter
Min.
Standard
Unit
Max.
200
100
100
t
c(TA)
tw(TAH)
tw(TAL)
ns
ns
TAiIN Input HIGH Pulse Width
TAiIN Input LOW Pulse Width
Symbol Parameter
Min.
Standard
Unit
Max.
100
100
t
w(TAH)
tw(TAL)
ns
ns
ns
ns
ns
TAiOUT Input Cycle Time
TAiOUT Input HIGH Pulse Width
TAiOUT Input LOW Pulse Width
TAiOUT Input Setup Time
TAiOUT Input Hold Time
Symbol Parameter
Min.
Standard
Unit
Max.
2000
1000
1000
400
400
t
c(UP)
tw(UPH)
tw(UPL)
tsu(UP-TIN)
th(TIN-UP)
Table 22.62 Timer A Input (Two-phase Pulse Input in Event Counter Mode)
ns
ns
ns
TAiIN Input Cycle Time
TAiOUT Input Setup Time
TAiIN Input Setup Time
Symbol
Parameter
Min.
Standard
Unit
Max.
800
200
200
t
c(TA)
tsu(TAIN-TAOUT)
tsu(TAOUT-TAIN)
Table 22.57 Timer A Input (Counter Input in Event Counter Mode)