Rose electronic ULTRAMATRIX 2xE Switch User Manual


 
ULTRAMATRIX E-SERIES MANUAL
39
Mode (Default: Share)
Assigns 1 of 4 modes to a profile. To change the mode, select the
profile to change the mode, then select the mode to change and press
[Enter]. A selection box will display. Select the mode needed and
press [Enter]. The modes are:
View – Profiles set to the view mode allow users to switch to any
computer, but have no keyboard or mouse control, only view
privileges.
Share – Profiles set to the share mode allow users to take
keyboard and mouse control of a computer on a first come, first
serve basis. Control of the computer is based on the time-out value
entered in the share column.
Control – Profiles set to the control mode allow users to take
exclusive control of a computer. No time-out value is invoked.
Other users that try to connect to the same computer can only view
the video. They have no keyboard or mouse control until the user
with the control disconnects from the computer.
Private – This mode is the same as the control mode except other
users cannot view the video or access the computer.
Share (Default: 2 seconds)
This feature allows other users to take keyboard and mouse control of
a computer after a specific time of no keyboard or mouse activity by a
user. To change the Share time for a given profile, select the profile,
then the Share to change and press [Enter]. An input box will display.
Type in a new share value in seconds and press [Enter]. Valid share
values are 0 to 9999 seconds. The share value is only valid if the
profile mode is share.
Scan (Default: 5 seconds)
When a user invokes the scan function, this feature sets the time the
video is displayed before switching to the next sequential computers
video. To change the scan rate, select the profile, then the scan rate to
change and press [Enter]. An input box will display. Type in a new
scan time and press [Enter]. Valid scan times are 0 to 9999. If the
video is not present during the scan mode, the scan value may be set
to low and the monitor cannot synchronize to the video fast enough to
display it. This usually happens with a scan value of 4 or lower. If this
problem occurs, increase the scan value. 0 (zero) is a valid entry but
not recommended.