Option 4. Send this Unit’s Main Program to other Units.
Option 5. Send this Unit’s Kernel to other Units.
The main program or kernel program updates (Option 3) only have to
be done on one port. Make sure power to all UltraMatrix switches is
“ON” and they are all connected using the appropriate expansion
cables.
Press 4 to send the main program to all other units, all other cards.
Press 5 to send the kernel program to all other cards.
The following messages will appear using either option 4 or option 5.
Before responding Y, make sure that the “Boards to update” number in
the message above agrees with the total number of boards in the entire
system minus 1. If the number does not agree, reply N, turn on the
inactive UltraMatrix Units, and press 4 or 5 again. When you reply Y,
the following message appears:
When complete, the system returns you to the serial options menu.
Wait at least 15 seconds before restarting the UltraMatrix after
choosing option 4 or 5 for the program to propagate to the other cards
in the system.
Option 6. Reset to Factory Defaults (This CPU card only)
NOTE: Before resetting any CPU card to factory defaults, note the
starting computer number listed on the Serial menu, Option 1. When
resetting a CPU card to factory defaults, this number will be set to one
(1) and must be changed back to the original value by using option 1 to
change the starting computer number and then saved using option 7.
In an expanded system, there cannot be two different UltraMatrix
switches in the system with the same starting computer number.
Boards to update - n
You are about to copy the firmware from this board to all other
boards in the system.
Are you sure? Y/N
Sending flash program code to system........................