Your Spectra Logic Technical Support representative may ask you to return
a problem component to Spectra Logic for servicing and failure analysis.
After you complete a replacement procedure, return the defective part
using ALL the packaging that the replacement part arrived in (including
any anti-static bags or foam inserts).
Use the return label and instructions that were included with the
replacement part when preparing to ship the component you are
returning. If you cannot locate these, contact Spectra Logic for another
copy (see Contacting Spectra Logic on page 4). The return label and RMA
printed on it are used to associate the returned component with your
account. To avoid being invoiced for failure to return the component, do not
ship the component back to Spectra Logic without the RMA return label.
APPENDIX B – SPECIFICATIONS
This section updates Appendix B, “Specifications.”
RAID Storage Specifications
The following table shows the RAID storage specifications for the
nTier700.
Caution
Severe damage can occur if the component is not packaged correctly. You may be
invoiced if it is damaged due to improper or insufficient packaging.
Parameter Specification
Drive Type 7200 RPM SATA
Single Drive capacity, native 1 TB or 2 TB
Capacity Options, native
a, b
Minimum, one blade
c
Maximum, six blades
c
a. The native capacity numbers refer to raw disk capacity; RAID configuration and system overhead reduce
the actual usable space; the usable capacity numbers are approximate.
b. In 10 drive increments, each increment being equal to one blade, up to sixty drives
c. Each blade contains ten 2 TB SATA drives.
10 TB
120 TB
RAID
RAID level
RAID controller write cache
Write cache memory battery backup
time
RAID 6
256 MB
Up to 72 hours with fully-charged
battery