Sun Microsystems 120 Server User Manual


 
10-2 Sun Fire V120 and Netra 120 Server User’s Guide December 2001
10.1 Introduction to the POST, obdiag, and
SunVTS Diagnostic Tools
The following diagnostic tools are available for the Sun Fire V120 and Netra 120
servers:
Power On Self Test (POST) Diagnostics
OpenBoot Diagnostics (obdiag)
SunVTS
If you need to contact Sun to report a problem with your system, it will help the
engineers to resolve the problem if you can provide relevant diagnostic information
from these tools.
10.1.1 Using POST Diagnostics
To view Power On Self Test (POST) diagnostic and error messages you need to have
a serial connection set up to the server. For more information, see “Setting Up Serial
Connections” on page 6-4.
If your system has the OpenBoot PROM (OBP) variable diag-switch? set to true,
then POST diagnostics will run automatically when you power on the server.
However, the default setting for diag-switch? is false.
To start POST diagnostics, at the ok prompt, do the following:
1. Type:
2. Type:
where value is either min or max (depending on the quantity of diagnostic
information you want to see).
3. Type:
ok setenv diag-switch? true
ok setenv diag-level value
ok reset-all