Sun Microsystems 120 Server User Manual


 
5-4 Sun Fire V120 and Netra 120 Server User’s Guide December 2001
2. Loosely screw the two parts of the slide mounts together, using the M4 nuts
supplied.
3. Measure the distance between the front and back posts of your rack.
4. Adjust the slide mounts so that the distance between the front and back mounting
ears is approximately the distance between the front and back posts of the rack.
5. Move the brackets so that the studs are in suitable slots, and tighten the nuts.
6. Fasten the mounting slides to the rack, using the screws supplied.
For the Sun StorEdge 72-inch rack, refer to
FIGURE 5-4 and FIGURE 5-5. Leave the
screws slightly loose to allow adjustment when you slide the server into the rack.
For a standard 19-inch rack, refer to
FIGURE 5-6. Leave the screws slightly loose to
allow adjustment when you slide the server into the rack.