Sun Microsystems 6.0005E+11 Computer Hardware User Manual


 
9-12 Ultra Enterprise 6000/5000/4000 Systems ManualNovember 1996
9
a. Type:
b. In the show-devs listing, find the node names.
Node names take the general form /sbus@3,0/SUNW,hme@3,8c00000.
Solution 1
Use this method while the operating system is running:
1. Become superuser.
2. Type:
3. Reboot the system (when convenient) to make the changes effective.
Solution 2
Use this alternate method when the system is already in OpenBoot:
1. At the monitor OpenBoot prompt, type:
2. Reboot to make the changes effective.
ok show-devs
# eeprom nvramrc=”probe-all install-console banner apply disable-link-pulse device-name
(Repeat for any additional device names.)
# eeprom “use-nvramrc?”=true
ok nvedit
0: probe-all install-console banner
1: apply disable-link-pulse device-name
(Repeat this step for other device names as needed.)
(Press CONTROL-C to exit nvedit.)
ok nvstore
ok setenv use-nvramrc? true