Sun Microsystems 6.0005E+11 Computer Hardware User Manual


 
10-6 Ultra Enterprise 6000/5000/4000 Systems ManualNovember 1996
10
10.5 Defective Disk Board
The disk board is hot-pluggable.
Figure 10-5 Diagnosing Disk Board Problems
INDICATION
System error message or
LED code identifies a
specific board
Board not identified or
intermittent problem
Begin
End
TEST/PROCEDURE
Locate indicated board.
Check LEDs on boardto verify ASR
has deactivated the board.
Set the SCSI IDs of the
replacement drives.
Replace the board or device.
Board is not active until system is
booted.
Check /var/adm/messages
Locate defective SCSI device with
probe-scsi-all (OpenBoot
command).
Check ID jumpers on board
REFERENCE
LED code must be Off-On-Off. See
Table 9-2.
See Appendix C, “SCSI Devices.”
See Section 3.3, “Hot-Plug Feature.”
Section C.2, “Disk Board Target IDs.”