2-4 Ultra Enterprise 6000/5000/4000 Systems Manual—November 1996
2
FUSE REPLACEMENT For continued protection against risk
MARKING of fire and electric shock, replace
ONLY with fuse of the same type and
rating.
Ensure that the voltage and frequency of the power outlet to be used matches
the electrical rating labels on the equipment.
Wear antistatic wrist straps when handling any magnetic storage devices,
CPU/Memory boards, or other printed circuit boards.
Use only properly grounded power outlets as described in Section 1.3,
“Preparing the Electrical Circuits,” in the Ultra Enterprise 6000/5000/4000
Systems Installation Guide, part number 802-3844.
Caution – DO NOT make mechanical or electrical modifications to the cabinet.
Sun Microsystems™ is not responsible for regulatory compliance of modified
cabinets.
Caution – The chassis AC power cord must remain plugged in to ensure a
proper ground.
2.3 Tools Required
This list represents the minimum of tools and test equipment you will need:
• Screwdriver, slotted, 3/16 inch
• Screwdriver, Phillips #2
• Screwdriver, Phillips #1
• Hex driver, M-4
• Hex driver, 3/16 inch
• Hex driver, 9 mm
• Wrench, 13 mm
• DIP/IC extraction tool
• ESD mat
• Grounding wrist strap
• Needlenose pliers
• Hex driver, 3/32
!
!
!