Symbol Technologies ES3000 Switch User Manual


 
B-5
B.5.6 Patch Cables
When installing equipment, replace old patch panel cables that do not meet Category 5e
specifications. As pointed out in the NEXT section, this near end piece of cable is critical for
successful operation.
B.5.7 Optimum Performance
For optimum performance of the 1000BASE-T product, it is important to fully qualify the cable
installation and ensure it meets or exceeds ANSI/EIA/TIA-568-A:1995 or ISO/IEC 11801:1995
Category 5 specifications. Install Category 5e cable where possible, including patch panel cables.
Minimize transition points, jacket removal, and untwist lengths. Bundling of cables is required to be
properly installed to meet the requirements in ANSI/EIA/TIA-568A-3.