Tests and Diagnostics
3-130 [CONFIDENTIAL]) PORTÉGÉ R700 Series Maintenance Manual (960-833))
3.34.6.9 FDD Test
1) Test content
This test accesses a file on a floppy disk and verifies that the access can be made correctly.
Create a file with the specified size on a floppy disk and delete the file after creating it
Perform the test after inserting a floppy disk to the drive.
■ Simple Mode
This test mode creates a 128 KB file (Write), reads the file and compares it with the original
file.
■ Detail Mode
This test mode creates a 384 KB file (Write), reads the file and compares it with the original
file.
2) Test screen
▼ Test detail: The drive under test execution is displayed..
▼ Progress status: Displays the progress status of the test with the progress bar.
3) Result judgment
■ In the case of PASS
The PASS Count display on the test screen is zoomed in and (OK) is displayed in the Result
field on the WinPE T&D screen
■ In the case of FAIL
The Error Count on the test screen is zoomed in and (NG) is displayed in the Result field on
the WinPE T&D screen.
The detail of the error is printed to the log of WinPE T&D. More details are as shown below.