4 Replacement Procedures 4.18 System board
4-50 [CONFIDENTIAL] PORTÉGÉ R700 Maintenance Manual (960-833)
2. Turn up the insulator and disconnect the LCD harness from the connector CN5300
on the system board.
3. Disconnect the DC-IN harness from the connector CN8800 on the system board.
Figure 4-29 Removing the system board (2)
LCD harness
DC-IN harness
Insulator
CN8800
CN5300