ZyXEL Communications 4728F Switch User Manual


 
Chapter 46 Access Control
XGS-4526/4528F/4728F User’s Guide
407
46.3.4 Configuring SNMP
From the Access Control screen, display the SNMP screen. You can click Access
Control to go back to the Access Control screen.
Figure 218 Management > Access Control > SNMP
The following table describes the labels in this screen.
rmon RmonRisingAlarm 1.3.6.1.4.1.890.1.5.1.1.16
.0.1
This trap is sent when a variable
goes over the RMON "rising"
threshold.
RmonFallingAlarm 1.3.6.1.4.1.890.1.5.1.1.16
.0.2
This trap is sent when the
variable falls below the RMON
"falling" threshold.
cfm dot1agCfmFaultAlarm 1.3.111.2.802.1.1.8.0.1 The trap is sent when the
Switch detects a connectivity
fault.
Table 150 SNMP Switch Traps (continued)
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
Table 151 Management > Access Control > SNMP
LABEL DESCRIPTION
General Setting Use this section to specify the SNMP version and community (password)
values.
Version Select the SNMP version for the Switch. The SNMP version on the Switch
must match the version on the SNMP manager. Choose SNMP version 2c
(v2c), SNMP version 3 (v3) or both (v3v2c).
Note: SNMP version 2c is backwards compatible with SNMP
version 1.