ZyXEL Communications 4728F Switch User Manual


 
Chapter 48 Syslog
XGS-4526/4528F/4728F User’s Guide
432
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_CRITICAL system voltage has recovered to
normal state
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_CRITICAL <FAN1 | FAN2> RPM value <value> is
lower than its limit RPM value
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_CRITICAL The RPM of the fan has recovered to
normal state
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_EMERGEMC
Y
<BOARD | MAC | PHY> temperature
value <value> exceeds its limit
temperature value
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_EMERGEMC
Y
system temperature has recovered to
normal state
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_ERR Restore system configuration failed
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_ERR Load factory default configuration
failed
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_ERR Gets the time and date from a time
server failed
SP_SYSLOG_TYPE_IP SYSLOG_INFO Ping probe to <target ip address>
failed
SP_SYSLOG_TYPE_IP SYSLOG_INFO Ping test to <target ip address> failed
SP_SYSLOG_TYPE_IP SYSLOG_INFO Ping test to <target ip address>
completed
SP_SYSLOG_TYPE_IP SYSLOG_INFO Trace path to <target ip address>
completed
SP_SYSLOG_TYPE_IP SYSLOG_INFO Trace path to <target ip address>
failed
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_INFO Traffic of type <type> from port
<port> is abnormal
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_INFO System bootup
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_INFO System init completed
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_INFO Save system configuration successfully
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_INFO Save system configuration <index>
successfully
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_INFO Save system configuration failed
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_INFO Upgrade system firmware successfully
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_INFO Upgrade system firmware failed
SP_SYSLOG_TYPE_SWIT
CH
SYSLOG_INFO Restore system configuration
successfully
Table 161 Syslog Messages
LOG TYPE SEVERITY MESSAGE