ZyXEL Communications 4728F Switch User Manual


 
Chapter 49 Cluster Management
XGS-4526/4528F/4728F User’s Guide
440
49.3 Clustering Management Configuration
Use this screen to configure clustering management. Click Configuration from
the Cluster Management screen to display the next screen.
Figure 238 Management > Clustering Management > Configuration
The following table describes the labels in this screen.
Table 165 Management > Clustering Management > Configuration
LABEL DESCRIPTION
Clustering
Manager
Active Select Active to have this Switch become the cluster manager switch.
A cluster can only have one manager. Other (directly connected)
switches that are set to be cluster managers will not be visible in the
Clustering Candidates list. If a switch that was previously a cluster
member is later set to become a cluster manager, then its Status is
displayed as Error in the Cluster Management Status screen and a
warning icon ( ) appears in the member summary list below.
Name Type a name to identify the Clustering Manager. You may use up to
32 printable characters (spaces are allowed).
VID This is the VLAN ID and is only applicable if the Switch is set to
802.1Q VLAN. All switches must be directly connected and in the
same VLAN group to belong to the same cluster. Switches that are not
in the same VLAN group are not visible in the Clustering Candidates
list. This field is ignored if the Clustering Manager is using Port-
based VLAN.