3Com 155 PCI Network Card User Manual


 
Verifying Driver Installation and Configuration 3-19
10 Click OK when the TCP/IP configuration is complete.
The restart prompt shown in Figure 3-11 appears.
Figure 3-11 Restart Prompt for Adapter Driver
11 Make sure that all cables are connected to the appropriate
switch ports.
12 Select Restart Now to restart the Windows NT system.
This completes the installation and configuration of the
3Com ATMLink Windows NT network driver.
Verifying Driver Installation and Configuration
Perform the following procedures to verify that the driver is
installed and operative:
If you are using TCP/IP, ping the ATMLink end station that you
want to test.
Check the link LED.
The LED is lit when the driver is loaded and a good connection
is made to the ATM switch. The LED on a standby NIC does not
light unless the NIC changes to active status.
Launch the ATMLink utility and check the State parameter in
the ELAN Information window. A functional ELAN is
designated as OPERATIONAL.
Check the Windows NT events log for any messages about
the newly configured ELANs and NICs.