3Com 3C13701 Network Router User Manual


 
3Com Router 5000 and Router 6000 v2.41
Module Guide
Chapter 2 Smart Interface Cards
2-24
Attribute Description
Number of connectors
1 (Router 1-Port Analog Modem SIC)
2 ()
Cable type Telephone cable with ferrite core
Maximum speed 56kbps
Supported standard
ITU-T V.90, V.34 (33.6 kbps), V.FC, V.32 bis, V.32, V.22 bis,
V.22A/B, V.23, V.21, Bell 212A a, Bell 103.
Supported service
Modem dial-up
2.6.4 Interface LEDs
Figure 2-24 Router 1-Port Analog Modem SIC panel
Table 2-15 Description of the LEDs on Router 1-Port Analog Modem SIC panel
LED Description
LINK
OFF means the link is idle. ON means the connection has been established.
Blinking means the connection is being set up.
ACT
OFF means the link is idle. Blinking means data is being transmitted or
received.
2.6.5 Interface Cable
The connection cables for Router 1-Port Analog Modem SIC are telephone cables with
ferrite core. Both ends of the cables are RJ11 connectors. For cable pinouts, refer to
Low-End and Mid-Range Series Routers Cable Manual.
Caution: