3Com 980-000077/002 Network Router User Manual


 
2-8 C
HAPTER
2: B
RIDGING
AND
IP
3
Enter
REM
to display the Remote Units screen.
4
If the central site unit name and IP address are not listed, make a
manual call of 5 minutes duration.
5
Enter
CALL
followed by the central site number.
6
While the call is up, press [Ctrl]+[V] at frequent intervals to refresh
the Remote Units screen. When the central site unit name appears,
cancel the manual call.
7
Enter
CANC
followed by the central site number. Follow step 1 in this
section for testing the IP Autocall and ISDN Number tables.
If the central site unit name is not listed on the Remote Units screen
after 5 minutes, carefully check the configuration of both the remote
and central site units.
8
Enter
QUIT
to close the remote management session or press
[Ctrl]+[D] if that command cannot be used.
Configuring a Remote Unit from the Central Site
A unit at a remote site can be remotely configured as an IP bridge.
The remote management and configuration capability allows the unit
to be configured from the central site, without the need for a
technician to travel to a remote site.
It is good practise to have ensured that the remote unit was restored
to the factory default settings before being despatched to the
remote site.
CAUTION:
Prior to despatch, it is essential that the unit has the ISDN
Network Type field configured to match the ISDN network type at
the remote site.
Prior to Despatch
Power on the unit and follow the sequence of steps for resetting the
unit to the factory default configuration, as described in “Manual
Configuration of a Central Site Unit for Bridging and IP” on
page 2-3.
Get_con.bk : BRID_IP.FRM Page 8 Friday, October 3, 1997 1:49 PM