3Com 980-000077/002 Network Router User Manual


 
Configuring a Remote Unit from the Central Site 2-9
Configure the ISDN network type to the correct setting for the
remote site, following the sequence of steps described in “Configure
the ISDN Network Type” on page 2-4.
When the unit is received at the remote site, ensure that it is
powered on and that the ISDN Port is connected to a correctly
functioning ISDN line, using the supplied ISDN cable.
Configuring the Central Site Unit
The central site unit must be correctly configured with the following
parameters:
Unit name (see page 2-4).
A valid IP address (see page 2-4).
The correct ISDN network type (see page 2-4).
Configure the ISDN Numbers Table on the Central Site Unit
The ISDN Numbers table entry on the central site unit must be
completed with the name that the remote unit will have, once that
unit has been fully configured.
1
Enter CO IS NU to display the ISDN Numbers screen.
2
Enter ADD to add a new entry to the numbers table.
3
Type the name
assigned to the remote unit
in the Name field and the
ISDN number for that unit in the ISDN Number 1 field.
Unit names are case-sensitive and must be entered correctly.
4
Press [Ctrl]+[E] to submit the new setting and then enter SAVE
Configure the ISDN Autocall Table on the Central Site Unit
The ISDN Autocall table entry must be completed with the IP address
which the remote unit will have, once that unit has been fully
configured.
1
Enter CO IS AUTO IP to display the ISDN IP Autocall Addresses
screen.
2
Enter ADD to add an entry to the ISDN Autocall Addresses table.
Get_con.bk : BRID_IP.FRM Page 9 Friday, October 3, 1997 1:49 PM