3Com 980-000077/002 Network Router User Manual


 
Configuring a Remote Unit from the Central Site 5-13
The frame type must be correct for the network environment in which
the unit is operating. If the frame type is not correct, the unit will not
pass data. Contact the network administrator for more information
about the frame type used.
7
Press [Ctrl]+[E] to submit the new setting.
The remote configuration session is disconnected when the new
settings are submitted. Note that the configuration has not been
permanently saved.
8
Press [Ctrl]+[D] to return to the central site unit management screens.
9
If the Remote Units screen is not displayed, enter REM to display it.
The Remote Units screen should now contain the remote unit name
and IP address.
10
Select the remote unit using the Arrow keys and then enter REM
11
Enter PASSWORD when the Enter Password screen is displayed.
12
Enter SAVE to save the new configuration.
Configure the ISDN Numbers Table
Set up the ISDN numbers table to associate the central site unit name
with an ISDN number.
1
Enter CO IS NU to display the ISDN Numbers screen.
2
Enter ADD to add a new entry to the numbers table.
3
Type the name of the
central site
unit in the Name field.
Unit names are case-sensitive and must be entered correctly.
4
Type the ISDN number of the central site unit in the ISDN Number 1
field.
It is very important to remember that Novell IPX routing uses
numbered
links. This means that the ISDN line between this unit and the central site
represents an additional Novell network and has to be assigned a valid
Novell network number.
5
Type the IPX network address of the
numbered link
in
the IPX
Network field, not the IPX network address of the central site unit.
Get_con.bk : IPX_ROUT.FRM Page 13 Friday, October 3, 1997 1:49 PM