Agilent Technologies 8714ET Switch User Manual


 
1-20 LAN Interface Supplement
Connecting and Configuring the Analyzer
Using BOOTP
2. Clear your current network configuration information.
a. Press
.
b. Press
.
c. Press
.
3. Create an IBASIC file that, when run, will clearly indicate the
successful retrieval and execution of the file. Store it on the BOOTP
server. Here's an example:
10 ASSIGN @Hp8712 TO 800
20 OUTPUT @Hp8712;"DISP:ANN:TITL ON"
30 OUTPUT @Hp8712;"DISP:ANN:CLOC:MODE OFF"
40 OUTPUT @Hp8712;"DISP:ANN:TITL1:DATA 'BOOTP is here!!!'"
50 END
4. Cycle power to your analyzer. After your analyzer boots, the network
IP address, gateway address and subnet mask should be those values
provided by the BOOTP server.
If you have a boot file set up correctly, your analyzer should also
retrieve and execute your boot file. If you used the example program
above, the screen will display
BOOTP is here!!!
SYSTEM OPTIONS
LAN
LAN Port Setup
871xxx IP Address
81xxx IP Address
Clear Entry
Etry
Enter
SYSTEM OPTIONS
LAN
LAN Port Setup
Gateway IP Address
81xxx IP Address
Clear Entry
Etry
Enter
SYSTEM OPTIONS
LAN
LAN Port Setup
Subnet Mask
81xxx IP Addre
Clear Entry
Etry
Enter