Step 6. Select the SAT Frequency to Test field and select the frequency (or frequencies) from
the drop-down Choices: list. The available selections are: 5970 Hz, 6000 Hz, 6030 Hz,
or All (which tests all frequencies).
Step 7. If you plan to test an AMPS Setup radio (or perhaps several radios), you may elect to test
the radio unconditionally, even if the MSC procedures would prefer that you not take the
radio out of service. To do this, select the Remove SU Radios Unconditionally field,
and press the knob to toggle it to YES.
Step 8. Select the TX Ant Port Cable Loss [dB] field and either turn the knob to the desired
value and press the knob to select that value, or use the DATA ENTRY keys to enter a
value and either press the
Enter key or press the knob to select that value. This value is
the loss through the cable used to connect the Test Set RF IN/OUT port to the end of the
transmit antenna foam jumper out of the Antenna Interface Frame during out-of-service
testing (see Figure 3-2 on page 57).
Step 9. Select the TX Test Port Cable Loss [dB] field and either turn the knob to the desired
value and press the knob to select that value, or use the DATA ENTRY keys to enter a
value and either press the
Enter key or press the knob to select that value. This is the
loss through the cable used to connect the Test Set ANT IN port to the coupled test port
in the Antenna Interface Frame during in-service testing (see Figure 3-1 on page 56).
Step 10. Select the TX Coupling field for each Base Station TX Test Port in the Antenna
Interface Frame and enter the coupling factor to be used during tests. To do this, either
turn the knob to the desired value and press the knob to select that value, or use the
DATA ENTRY keys to enter a value and either press the
Enter key or press the knob to
select that value. If you do not know the coupling factor(s), run the “TX Test Port
Coupling Measurements” on page 88 to measure it.
Step 11. Press the
k5 (Return) key to return to the Lucent AMPS Tests Main Menu screen.