Agilent Technologies E6385A Whiteboard Accessories User Manual


 
Performing Tests
RX Gain Test
Chapter 4
79
Performing Tests
RX Gain Test
This test measures the gain through RX devices such as the low-noise amplifiers in a
Base Station.
CAUTION This test is designed to measure the gain through only low-output-power elements.
This test uses the Test Set ANT IN port to measure the output level of the TTU. Input
levels to this port greater than 60 milliwatts (17.8 dBm) might damage the Test Set.
Therefore, the power output of the unit under test must not exceed 60 milliwatts.
Parameters and Specifications Used
The following parameters and specifications are used when running this test. See
Chapter 5, “Reference,” on page 95 for descriptions of the parameters and specifications.
Parameters:
17. MSC BTS Type [1=Series II 2=M 3=MM]
Specifications (Pass/Fail Limits):
None used for this test.