Agilent Technologies E6385A Whiteboard Accessories User Manual


 
Performing Tests
TX –39 dBm Power Test
Chapter 4
O:\Manuals\E6385A_Amps\Book\perftst.fm
82
Parameters and Specifications Used
The following parameters and specifications are used when running this test. See
Chapter 5, “Reference,” on page 95 for descriptions of the parameters and specifications.
Parameters:
3. GN Power Output [0=meas 1=spec 2=blnk]
21. TX Antenna Port Cable Loss
30. TX Test Port Cable Loss
Specifications (Pass/Fail Limits):
10. Output Power Error
Select and Run the Test
Select and run the TX
39 dBm Power Test as follows:
Step 1. Take the selected antenna face, out of service. (Use the PC to dial into the MSC and
enter the craft shell, or call the MSC and instruct switch personnel as to which radio to
turn off.)
Step 2. Enter a frequency plan (see “Defining a Frequency Plan” on page 43).
Step 3. From the Lucent AMPS/TDMA Test Main Menu screen, select the Test Selections
field. The Test Software will display the Test Selections Menu screen.
Step 4. Select the TX
39 dBm Power Test field. The Test Software will display the TX
39 dBm
Power Test Menu screen.
Step 5. Select the Antenna Number field. Enter the antenna number by either turning the knob
to the desired number and pressing it, or using the DATA ENTRY keys to enter the
number, then either pressing the knob or the
Enter key to select it.
Step 6. Scroll to the Adjust Radio Power field and press the knob to toggle it to the desired
mode.
If you select Always, the radio power will be adjusted in every instance.
If you select On Failure, the radio power will be adjusted only on failure.