Remote Control
These results may be viewed directly as web pages or the result
file may be uploaded to a PC. The result file contains all of the
results for the test in Comma Separated Value (CSV) format for
use in spreadsheet programs.
Java
TM
generated reports are available for RFC2544 and VoIP
tests.
A User defined logo can now be included into Java Test Reports,
via the CF memory card.
To display logo in Java report, save the the image file of the logo,
in the size 250 pixels wide by 40 pixels high, as a .GIF file, with
the name customer.gif, in the directory
“<drive>\WSDATA1.0\logo\” on the Compact Flash Memory
Card.
The report will automatically scale the logo if it is larger,
however, providing an image with the recommended resolution
will provide a better effect.
By default, when users press the SAVE button, the FrameScope
creates a logo directory and “customer.gif” logo file with the
logo of Agilent Technologies.
Network Database Links to a list of stored station lists. These
station lists may be uploaded to the PC. The station lists are
stored in Comma Separated Value (CSV) format for use in
spreadsheet or database programs.
Remote Control Links to a page which shows an image of the
FrameScope’s display. Clicking on this image has the effect of
pressing the FrameScope’s display. The display is updated
when the user of the web interface clicks on the screen or every
10 seconds if no screen operations are performed.
Error Log Links to a list of errors found on the network.
NOTE
If the FrameScope is currently running one of the tools (Autotest, RFC
2544, IP/MAC Loopback or Statistics) in any of the FrameScope screens,
its respective stored data or test results in the FrameScope cannot be
displayed. For example, if you are running Statistics on the FrameScope,
you cannot view the Statistics database from the remote screen.