Agilent Technologies N2620A Network Card User Manual


 
Network Performance Analyzer Reference 5
Memory Requirements
Agilent FrameScope Pro User’s Manual 163
Memory Requirements
The FrameScope Pro requires a CompactFlash™ card to store
test results and network station lists. The amount of memory
that each Autotest result takes up depends on the number of
test and the number of iterations that you set before starting the
test. The results require about 600 bytes per test plus 150 bytes
per iteration for each test. There is a limit of 100 tests and a
limit of 100 iterations. Therefore, the maximum results size is
about 1.5 MB.
The Autotest suite storage requirement is only 350 bytes per
test, so the maximum size is about 35 KB.
The station list storage requirement is 250 bytes per station
with a maximum of about 1500 stations, so the maximum size is
375 KB.
The FrameScope Pro does not use any of the 4MB of internal
Flash memory for network test result storage.
The following table lists approximate record storage capacities
when configured for a 32 MB removable CompactFlash™ card
and for comparison, a 192 MB card. All sizes of CompactFlash™
will work as FrameScope Pro Network Autotest results storage.
Saved Test Results Capacities, assuming a 1 MB used for test suites and station lists
Autotest # Iterations Size of
record
Capacity (# of
Records)
32 MB
CFlash
Card
192 MB
CFlash
Card
10 Autotests 1 60 KB 516 3183
10 Autotests 100 156 KB 198 1224
100
Autotests
1 600 KB 51 318
100
Autotests
100 1.56 MB 19 122