Agilent Technologies N2620A Network Card User Manual


 
Network Testing with the FrameScope Pro 2
WireMap Adapter Testing
Agilent FrameScope Pro User’s Manual 77
WireMap Adapter Operation
When the wiremap adapter is connected to the FrameScope, the
FrameScope sends a sequence of DC, TTL level signals through
the wire pairs in order of a few 100 milliseconds. For each step
of this sequence of signalling, the DC voltage is measured by the
receiver of the FrameScope. The FrameScope software
identifies wiremap information based on the readings.
LED Indicators
The wiremap adapter has four LEDs, each connected to a wire
pair. The wiremap adapter has four LEDs, each connected to a
wire pair. During the test, the LEDs flash. Once the test is
completed, the LEDs turn off.
Procedure for WireMap Testing
1 Connect the FrameScope and cable under test to the
WireMap Adapter.
2 From the Network Main Menu, press
Tools, then press WireMap.
3 Click Start Test.