Bosch Appliances 3122 475 22015en Webcam User Manual


 
INTEGRUS | Installation and User Instructions | Integrus Charging Units en | 51
Bosch Security Systems | 2005-04 | 3122 475 22015en
5.2 Wall mounting the charging
cabinet
LBB 4560/50 is suitable for either table-top or wall-
mounted use.
It can be wall-mounted using 5 mm (0.19 inch) screws,
with a head diameter of 9 mm (0.35 inch). The screws
and plugs delivered with the LBB 4560/50 are
designed to mount the unit on a solid brick or concrete
wall. Two holes, 8 mm in diameter and 55 mm in
depth, must be drilled 500 mm apart (see figure 5.2).
5.3 Charging procedure
Ensure that the charging unit is connected to the mains
and that it is switched on. Place the receivers firmly in
the charging compartments. The charging indicator
LEDs on all receivers should illuminate. These LEDs
indicate the charging status of each receiver:
LED colour Charging status
Green Charging completed.
Red Charging in progress.
Red blinking Error status. See chapter 6,
Trouble-shooting.
Off Charger switched off or receiver not
properly inserted.
Warning: To comply with UL and CSA
regulations, the charging cabinets must
be mounted in such a way that they can
be easily removed by hand in case of
emergency.
Figure 5.2 Charging cabinet mounting dimensions
Notes:
It is preferred to switch on the charg-
ing unit before inserting the receivers.
Receivers can be inserted or removed
without damage while the charging
unit is switched on.
Charge the battery pack to full capaci-
ty before using them for the first time.
The charger always applies fast
charge during the first 10 minutes
after inserting a receiver. Inserting the
receiver multiple times with a fully
charged battery pack should therefore
be avoided, as this will damage the
battery pack.
Continuously charging the receiver
will not damage the receiver or bat-
tery pack. Receivers can therefore
safely be left in their charging posi-
tions when they are not used.
When the rechargeable battery pack
is used, it is advisable to check regu-
larly after three years that the batter-
ies are not leaking. If there is any sign
of leakage or corrosion, replace the
battery pack. Ensure that only the bat-
tery pack LBB 4550/00 is used. The
battery pack has to be replaced at
least every five years.