- 113 -
fn=0、48: Function 0 Erasing Specified Record
GS ( C pL pH m fn b kc1 kc2
[Code] <1D>H<28>H<43>H<pL><pH><m><fn><b>[c1 c2]
[Range] (pL+pH×256)=5(pL=5、pH=0)
m=0
fn=0、48
b=0
32≦c1≦126
32≦c2≦126
[Outline] [The specification which is common to the model]
Erases the record specified by c1, c2 stored in user NV memory.
fn=1、49: Function 1 Storing Data to Specified Record
GS ( C pL pH m fn b c1 c2 d1...dk
[Code] <1D>H<28>H<43>H<pL><pH><m><fn><b>[c1 c2][d1...dk]
[Range] 6≦(pL+pH×256)≦65535(0≦pL≦255、0≦pH≦255)
m=0
fn=1、49
b=0
32≦c1≦126
32≦c2≦126
32≦d≦254
k=(pL+pH×256)-5
[Outline] [The specification which is common to the model]
• Stores data to the record specified by c1, c2.
• When the data is present in NV memory, it is replaced by new data.