- 212 -
fn=70: Function 70 Setting Options for PDF417
GS ( k pL pH cn fn m
[Code] <1D>H<28>H<6B>H<pL><pH><cn><fn><m>
[Range] (pL+pH×256)=3(pL=3、pH=0)
cn=48
fn=70
m=0、1
[Outline] [The specification which depend on the model]
Specifies or clears the PDF417 option.
m Function
簡易 PDF417 の処理を解除
0
簡易 PDF417 の処理を指定
1
[Caution] • When cleared with m=0, standard processing for PDF417 is conducted thereafter.
[Default] m=0
fn=80: Function 80 Storing received data to 2-dimensional code data storage
area
GS ( k pL pH cn fn m d1...dk
[Code] <1D>H<28>H<6B>H<pL><pH><cn><fn><m><d1…dk>
[Range] 4≦(pL+pH×256)≦65535(0≦pL≦255 、0≦pH≦255)
cn=48
fn=80
m=48
0≦d≦255
k=(pL+pH×256)-3
[Outline] [The specification which depend on the model]
Stores PDF417 2-dimensional code data (d1…dk) to 2-dimensional code data storage area.
• Processes [(pL+pH×256)-3] of d1 and thereafter as 2-dimensional code data.
[Sample Program]
[Print Results]
Refer to Sample Program and Print Results for fn=81: Function181.