- 278 -
●MSW1-5: CR code
[Outline] Select the printer when receiving CR(<0D>H) code.
OFF(0) ON(1)
CR mode Ignored LF
ON (1) OPERATION:
Select the same operation with LF when receiving CR code.
Print data in print buffer and put linefeeds as specified.
OFF (0) OPERATION:
CR code may be ignored with no actions if receiving CR code.
●MSW1-6: Reserved [Fixed to OFF (0)]
●MSW1-7: DSR signal
[Outline] Printer can be reset with DSR (serial I/F-6pin) signal. Select enable/disable of reset function with
this signal.
OFF(0) ON(1)
DSR Signal Invalid Valid
ON (1) OPERATION: Used as reset signal
OFF (0) OPERATION: Not used as reset signal
●MSW1-8: INIT signal
[Outline] Printer can be reset with INIT (serial I/F-25Pin) signal. Select enable/disable of reset function with
this signal.
OFF(0) ON(1)
INIT Signal Invalid Valid
ON (1) OPERATION: Used as reset signal
OFF (0) OPERATION: Not used as reset signal