- 197 -
fn=11: Function 11 Setting Communication Conditions
GS ( E pL pH fn a d1...dk
[Code] <1D>H<28>H<45>H<pL><pH><fn><a><d1>...<dk>
[Range] 3≦(pL+pH×256)≦65535(0≦pL≦255、0≦pH≦255)
fn=11
1≦a≦4 (Not changed in other than specified range)
48≦d≦57 (Not changed in other than specified range)
1≦k≦6
[Outline] [The specification which is common to the model]
Sets the communication conditions of serial interface specified by “a”.
• a = 1: Setting baud rate
d3 d4
Baud Rate d1 D2 d5 d6
●1200
49(“1”) 50(“2”) 48(“0”) 48(“0”) ---- ----
2400 50(“2”) 52(“4”) 48(“0”) 48(“0”) ---- ----
4800 52(“4”) 56(“8”) 48(“0”) 48(“0”) ---- ----
▲9600
57(“9”) 54(“6”) 48(“0”) 48(“0”) ---- ----
△19200
49(“1”) 57(“9”) 50(“2”) 48(“0”) 48(“0”) ----
38400 51(“3”) 56(“8”) 52(“4”) 48(“0”) 48(“0”) ----
●57600
53(“5”) 55(“7”) 54(“6”) 48(“0”) 48(“0”) ----
●115200
49(“1”) 49(“1”) 53(“5”) 50(“2”) 48(“0”) 48(“0”)
●・・・support by CT-S2000、CT-S4000、PMU2XXX
*PMU2XXX: Prohibit the use of 57600bps.
△・・・Default : CT-S300、CT-S2000(JPN/EUR)、CT-S4000(JPN/EUR)
、CT-S310
▲・・・Default : CT-S280、CT-S2000(USA)、CT-S4000(USA)、BD2-2220、PMU2XXX
• a = 2: Setting to specified parity
Parity Setting
d1
48 (Default) No parity
49 Odd parity
50 Even parity
• a = 3: Setting to specified flow control
Flow Control
d1
48 (Default) DSR/DTR
49 XON/XOFF
• a = 4: Setting to specified data length
Setting Data Length
d1
55 7-bit length
56 (Default) 8-bit length
• Operates only in printer function setting mode.
• Which of dip SW or memory SW is used at initialization depends on “Selecting communication
condition setting” of dip SW1-1.