- 126 -
GS g 0 m nL nH
CT-S280 CT-S300 CT-S2000 CT-S4000 BD2-2220 CT-S310
support model
PMU2XXX
[Function] Initializing maintenance counter
[Code] <1D>H<67>H<30>H<m><nL><nH>
[Range] m=0
20≦(nL+nH×256)≦70(nL=20、21、50、70、nH=0)
[Outline] [The specification which is common to the model]
Set the value of resettable maintenance counter specified to 0.
nL, nH are used to set the maintenance counter number to (nL+nH×256).
Counter Number
Counter [Unit]
Hex. Decimal
14 20
Paper-feed line[line]
15 21
Head powering count [times]
32 50
Auto-cutter drive count [times]
46 70
Product operation time[hours]
[Caution] • This command, if used frequently, may destroy NV memory, thus write command to NV memory
shall be used less than [10 times/day] as a guideline.
• Along with processing this command, during data-writing to NV memory, printer BUSY may occur.
During the printer BUSY, to stop receive processing, this printer prohibits the data sending