108
alarm_trigger_period
number of seconds that values above or below the alarm threshold can be received before an alarm is sent
(default 60)
alarm_auto_inhibit_period
number of seconds this alarm disabled after an alarm is sent (default 3600)
consolidation_fn
how to combine variables from rrd_updates into one value (default is sum - other choice is average)
rrd_regex
regular expression to match the names of variables returned by the xe vm-data-source-list uuid=<vmuuid>
command that should be used to compute the statistical value. This parameter has defaults for the named
variables cpu_usage, network_usage, and disk_usage. If specified, the values of all items returned
by xe vm-data-source-list whose names match the specified regular expression will be consolidated using
the method specified as the consolidation_fn.
Valid Host Elements
name
what to call the variable (no default)
alarm_priority
the priority of the messages generated (default 5)
alarm_trigger_level
level of value that triggers an alarm (no default)
alarm_trigger_sense
high if alarm_trigger_level is a maximum value otherwise low if the alarm_trigger_level
is a minimum value. (default high)
alarm_trigger_period
number of seconds that values above or below the alarm threshold can be received before an alarm is sent
(default 60)
alarm_auto_inhibit_period
number of seconds this alarm disabled after an alarm is sent (default 3600)
consolidation_fn
how to combine variables from rrd_updates into one value (default sum - other choice is average)
rrd_regex
regular expression to match the names of variables returned by the xe vm-data-source-list uuid=<vmuuid>
command that should be used to compute the statistical value. This parameter has defaults for the named
variables cpu_usage and network_usage. If specified, the values of all items returned by xe vm-data-
source-list whose names match the specified regular expression will be consolidated using the method
specified as the consolidation_fn.
Configuring Email Alerts
Note:
Email alerts are only available in a pool with XenServer Advanced edition or above. To find
out about XenServer editions and how to upgrade, visit the Citrix website here.
Alerts generated from XenServer can also be automatically e-mailed to the resource pool administrator, in
addition to being visible from the XenCenter GUI. To configure this, specify the email address and SMTP server:
pool:other-config:mail-destination=<joe.bloggs@domain.tld>
pool:other-config:ssmtp-mailhub=<smtp.domain.tld[:port]>
You can also specify the minimum value of the priority field in the message before the email will be sent:
pool:other-config:mail-min-priority=<level>