Dell MD3000i Network Router User Manual


 
Instructions to Configure BFi for Intel NIC 17
4
Record the IQN of the PowerVault MD3000i storage array in the
"Configuration Worksheet" on page 77:
a
Select the
iSCSI
tab, and then click
Change Target Identification
.
b
Record the iSCSI target name.
NOTE: The ISCSI Target Alias cannot be used by a host for booting.
5
Record the iSCSI host port IP addresses of the RAID controllers in the
"Configuration Worksheet" on page 77:
a
Select the
iSCSI
tab and click
Configure iSCSI Host Ports
.
b
Select each iSCSI host port from the drop down list. Record the IP
address of the port to which the host system is configured to boot
from. If the host system has redundant paths, select a port on a
controller that is on a separate subnet.
Configuring the Intel iSCSI Boot Menu
1
Use the iSCSI DOS utility located in the
iSCSI\DOS
directory on the
media that shipped with the Intel NIC to flash the Intel NIC with the
iSCSI Boot Programmable Read-Only Memory (PROM). For more
instructions, see the
Intel iSCSI Boot User Guide
.
Boot to a bootable MS-DOS
®
diskette drive or a bootable USB key and run
the
iSCSI DOS
utility using the following commands:
ISCSIUTL -ALL -FLASHENABLE
ISCSIUTL -ALL –UP
For additional help, type
ISCSIUTL -?
at a command prompt.
2
Boot into the
Intel iSCSI Boot Setup
menu. For more information, see
the
Firmware Setup
section in the
Intel iSCSI Boot User Guide.
a
Configure one NIC as
Primary
.
b
Enter the initiator name, IP address, subnet, and gateway of the host
that you recorded in step 1 of "Configuring the PowerVault MD3000i
Storage Array" on page 15.
c
Enter the IQN and IP address of the target.
d
Retain the default values of the port number as 3260 and LUN
number as 0, unless you need to change them.