46 Instructions to Configure BFi for Broadcom NIC
11
In the
Main Menu
, select
Initiator parameters
. Enter the IP address,
subnet, gateway, and DNS of the host.
12
Press <Esc> to go back to the
Main Menu
.
13
In the
Main Menu
, select
1
st
Target parameters
and enter the target’s
IP address and IQN. Retain the default values of the port number as
3260
and LUN number as
0
, unless you need to change them.
NOTE: Configuring the second iSCSI target is not supported at this time.
14
Press <Esc> twice to exit the
Configuration Menu
. Select
Exit and Save
Configuration
and press <Enter>.
NOTE: If Windows HBA mode is set to Enabled, skip step 15 to step 16. If you
are using iSCSI boot through HBA, redundant paths to the target are not
supported. You can create redundancy for Data I/O by creating a connection
manually in the Microsoft iSCSI initiator for the additional network adapters.
NOTE: Skip step 15 to step 16 if Windows HBA mode is set to Enabled.
Redundant paths to the target is not supported for iSCSI boot over HBA. You
can create redundancy for Data I/O by creating a connection manually in the
Microsoft iSCSI initiator for the additional Network adapters. Refer to the
iSCSI target user manual for specific guidance to create the connection.
15
Select
Secondary Device Parameters
. In the
Secondary Device Parameters
screen, select
Secondary Device
and press the <Enter> key. In the device
list, select the MAC address of the second adapter that you recorded in the
step 3.
16
Select
Configure Secondary
and press the <Enter> key. Repeats step 8 to
step 13 to configure the secondary adapter.
NOTE: If Windows HBA mode is set to Enabled, skip step 17 to step 19. If you
are using iSCSI boot through HBA, redundant paths to the target are not
supported. You can create redundancy for data I/O by creating a connection
manually in the Microsoft iSCSI initiator for the additional Network adapters.