Delta Electronics VFD-EL Power Supply User Manual


 
Chapter 4 Parameters|
4-94 Revision August 2008, 2ELE, V1.02
Content Address Function
Error code:
0: No error occurred
Status
monitor
Read only
2100H
1: Over-current (oc)
2: Over-voltage (ov)
3: IGBT Overheat (oH1)
4: Reserved
5: Overload (oL)
6: Overload1 (oL1)
7: Overload2 (oL2)
8: External fault (EF)
9: Current exceeds 2 times rated current during accel (ocA)
10: Current exceeds 2 times rated current during decel (ocd)
11: Current exceeds 2 times rated current during steady state
operation (ocn)
12: Ground Fault (GFF)
13: Reserved
14: PHL (Phase-Loss)
2100H 15: Reserved
Status
monitor
Read only
16: Auto accel/decel failure (cFA)
17: Software protection enabled (codE)
18: Power Board CPU WRITE failure (CF1.0)
19: Power Board CPU READ failure (CF2.0)
20: CC, OC Hardware protection failure (HPF1)
21: OV Hardware protection failure (HPF2)
22: GFF Hardware protection failure (HPF3)
23: OC Hardware protection failure (HPF4)
24: U-phase error (cF3.0)
25: V-phase error (cF3.1)
26: W-phase error (cF3.2)
27: DCBUS error (cF3.3)