Delta Electronics VFD-EL Power Supply User Manual


 
Chapter 4 Parameters|
4-22 Revision August 2008, 2ELE, V1.02
Overheat Warning
Applications Purpose Functions
Related
Parameters
Air conditioner Safety measure
When AC motor drive overheats, it
uses a thermal sensor to have
overheat warning.
03.00
04.05~04.08
Two-wire/three-wire
Applications Purpose Functions
Related
Parameters
General application
To run, stop,
forward and
reverse by external
terminals
V
FD-EL
MI1:("OPEN":STOP)
("CLOSE":FWD)
MI2:("OPEN": STOP)
("CLOSE": REV)
DCM
FWD/STOP
REV/STOP
MI1:("OPEN":STOP)
("CLOSE":RUN)
MI2:("OPEN": FWD)
("CLOSE": REV)
DCM
RUN/STOP
FWD/REV
V
FD-EL
3-wire
MI3:("OPEN":STOP)
MI1 ("CLOSE":RUN):
MI2:("OPEN": FWD)
("CLOSE": REV)
DCM
STO
P
REV/FWD
RUN
V
FD-EL
02.00
02.01
02.09
04.04
Operation Command
Applications Purpose Functions
Related
Parameters
General application
Selecting the
source of control
signal
Selection of AC motor drive control by
external terminals, digital keypad or
RS485.
02.01
04.05~04.08
Frequency Hold
Applications Purpose Functions
Related
Parameters
General application
Acceleration/
deceleration pause
Hold output frequency during
Acceleration/deceleration
04.05~04.08