Parameter Explanation Settings
Factory
Setting
Custome
r
07.02
Torque
Compensation
0.0 to 10.0 0.0
07.03 Slip Compensation 0.00 to 10.00 0.00
07.04
|
07.09
Reserved
07.10
Accumulative Motor
Operation Time
(Min.)
0 to 1439 Min. 0
07.11
Accumulative Motor
Operation Time
(Day)
0 to 65535 Day 0
07.12
Motor PTC
Overheat Protection
0: Disable
1: Enable
0
07.13
Input Debouncing
Time of the PTC
Protection
0~9999(*2ms) 100
07.14
Motor PTC
Overheat Protection
Level
0.1~10.0V 2.4
07.15
Motor PTC
Overheat Warning
Level
0.1~10.0V 1.2
07.16
Motor PTC
Overheat Reset
Delta Level
0.1~5.0V 0.6
07.17
Treatment of the
Motor PTC
Overheat
0: Warn and RAMP to stop
1: Warn and COAST to stop
2: Warn and keep running
0
Group 8 Special Parameters
Parameter Explanation Settings
Factory
Setting
Custome
r
08.00
DC Brake Current
Level
0 to 100% 0
08.01
DC Brake Time
during Start-Up