Dialogic SS7G2X Server User Manual


 
32
Chapter 5 Parameter Definitions
FTPPWD
FTP Password enabled parameter. Set to Y
to enable ftp password protection, or N to
disable password protection.
Y or N Default = Y
FTPSER
Indicates whether the Signaling Gateway
can act as a
ftp server or not. Set to Y to
enable the
ftp server, or N to disable the ftp
server.
Y or N Default = Y
GATEWAY
An IP gateway used to reach other networks
when the destination is not on the local sub-
net. Specified using dot notation, that is,
www.xxx.yyy.zzz
www – 0 to 255
xxx – 0 to 255
yyy – 0 to 255
zzz – 0 to 255
Default = 0.0.0.0
HPORT Host SCTP port 1 to 65535
2905 for M3UA
SNLINKs.
3565 for M2PA
SNLINKs.
INHIBIT
Invoke/revoke MTP3 management inhibiting
of an SS7 signaling link
Y or N Default = N
IPADDR
Internet Protocol (IP) address of the
Signaling Gateway Ethernet port 1 specified
using dot notation, that is, www.xxx.yyy.zzz
www – 0 to 255
xxx – 0 to 255
yyy – 0 to 255
zzz – 0 to 255
Default = 0.0.0.0
IPADDR2
Internet Protocol (IP) address of the
Signaling Gateway Ethernet port 2 specified
using dot notation, that is, www.xxx.yyy.zzz
www – 0 to 255
xxx – 0 to 255
yyy – 0 to 255
zzz – 0 to 255
Default = 0.0.0.0
IPADDR3
Internet Protocol (IP) address of the
Signaling Gateway LNKA port specified
using dot notation, that is, www.xxx.yyy.zzz
www – 0 to 255
xxx – 0 to 255
yyy – 0 to 255
zzz – 0 to 255
Default = 0.0.0.0
IPADDR4
Internet Protocol (IP) address of the
Signaling Gateway LNKB port specified
using dot notation: www.xxx.yyy.zzz
www – 0 to 255
xxx – 0 to 255
yyy – 0 to 255
zzz – 0 to 255
Default = 0.0.0.0
IPGW
Logical reference for an Internet Protocol
Gateway
1 to 31
IPNW
IP network identifier specified using dot
notation, that is, www.xxx.yyy.zzz
www – 0 to 255
xxx – 0 to 255
yyy – 0 to 255
zzz – 0 to 255
Default = 0.0.0.0
IR Logical reference for a incoming route 1 to 32
ITS
The input timeslot in a cross connection (in
the case of a duplex cross connection, this
is also the output timeslot for the reverse
direction). The format is:
xx-y-zz
where:
xx = board position (BPOS)
y = PCM within a board
zz = timeslot
xx – 1 to 3
y – 1 to 4
zz – 1 to 31
LABEL Text label.
0 to 12
<text character>
LC PCM line coding
One of:
•HDB3
•AMI
•B8ZS
Default =
•HDB3 for E1
•B8ZS for T1
LINES Number of MML lines per page 10 to 99 Default = 25
LSH Load share across link sets Y to N Default = N
LS
Logical reference of an SS7 link set, which
can contain a number of signaling links
1 to 64
Table 2. Parameter Definitions (Continued)
Name Description Range Notes