99
Dialogic
®
SS7G2x Signaling Server SGW Mode User Manual Issue 4
6.11.2 RDCRC – Remote Data Centre Continuous Record Change
Synopsis
This command changes the parameters for a continuous record collection for which collected data is
transferred via Ethernet to a Remote Data Centre (RDC).
The period is the maximum amount of time allowed before the transfer of a block of continuous records must
be performed.
The label is used as the directory name on the RDC that the files are written to.
Syntax
RDCRC:RECORD=,[PERIOD=,][MINREC=,][RDC1=,][RDC2=,][LABEL=];
Prerequisites
• The record must already be initiated.
• If specified, RDC1 must already be initiated.
• If specified, RDC2 must already be initiated
• If specified, RDC2 must not equal RDC1.
Limitations
• Before transfer to a RDC can take place, the directory (represented by the label) must exist on the
remote site.
• PERIOD must be in the range 30 seconds to 30 minutes.
Attributes
CONFIG
Examples
RDCRC:RECORD=1,PERIOD=00:05:00,MINREC=100,
RDC1=1,LABEL=ALARM;