Dialogic SS7G2X Server User Manual


 
35
Dialogic
®
SS7G2x Signaling Server SGW Mode User Manual Issue 4
RESTART
Specifies the type of restart operation,
which can be one of the following:
NORMAL - The system undergoes a full
system restart, resetting the hardware,
operating system and SIU software.
This is the default behavior. NORMAL
resets should be used for software
upgrade or for maintenance events.
SOFT - The system restarts the
application software. Prior to a soft
restart, the Signaling boards are reset.
SOFT resets may be used for a more
rapid system restart after updating the
system configuration or licenses.
However, if a new software distribution
is to be installed, the system performs
a NORMAL restart.
HALT - The system shuts down without
a subsequent restart.
Caution: Once the system has been
halted, the only way to restart the unit
is by physically pressing the Power
switch on the front panel of the
chassis.
One of:
•NORMAL
•SOFT
•HALT
RKI
Routing Key Index
An identifier for either a complete routing
key or part of a routing key.
1 to 512
RKTAB
Routing Key Table
A table of particular routing keys.
1 to 8
RTPRI Destination route priority
One of:
•NONE
•MTP
Default = NONE
RTS
A timeslot within a PCM interface on a board
used for monitoring information received by
the monitored object. The format is:
xx-y-zz
where:
xx = board position (BPOS)
y = PCM within a board
zz = timeslot
xx – 1 to 3
y – 1 to 4
zz – 1 to 31
SBITS Number of stop bits on V.24 port 1 to 2 Default = 1
SECURE
Secure operation. When active offers a
higher level of security. The use of the
parameter is command specific. See the
CNSYS and SNSLI command descriptions
for more information.
Y or N Default = N
SEQ Sequence number 1 to 32
SG Reserved
SI Reserved
SIGTYPE
Type of software loaded onto signaling
board
SS7
SLC
Signaling link code uniquely identifying a
signaling link within a link set
0 to 15
SNMP
Whether SNMP should be active on the
system
Y or N Default = N
SNRT Reserved
SNTYPE The type of operation of the SIGTRAN link
One of:
•SGM3UA
•M2PA
SNLINK Logical reference for a SIGTRAN link 1 to 200
Table 2. Parameter Definitions (Continued)
Name Description Range Notes